Used for saw-cut installations where a 3/16” groove is cut into the concrete or asphalt and the wire is stuffed and sealed (using loop sealent) into the surface. Custom polyethylene outer jacket protects a micro-dusted nylon coated inner jacketed 16AWG stranded wire. The saw-cut loop has a built in backer-rod securely fitting a 3/16” saw-cut groove eliminating the need to apply backer-rod to hold the loop to the bottom of the saw-cut groove and requires 30-40% less loop sealant to seal the groove. The entire loop including the lead-in fits within a 3/16” saw-cut groove preventing wasted time spent double saw-cutting or doubling blades to cut the home run lead-in.
The only preformed saw-cut loop with a true installation kit designed to ensure a perfectly size cut every time. See more about the TB-Kit.
Use this formula to calculate how far from the gate the loops should be place so that by the time a car reaches the gate, the gate will be completely open:
Exit Loop formula: x*(y*1.46)=z x = time for gate to open in seconds. y = Desired MPH to reach gate. z = how far from gate.
FYI - 1.46 converts miles per hour to feet per second. We also recommend adding in 10 to 20 feet so the gate is fully open at comfortable distance from the gate.
For placement of a safety loop before and after the gate use the formula below. A safety loop is designed to stop the motion of the gate before the car reaches the gate. The distance below should give an ample amount of time for the gate to stop before hitting a vehicle:
Safety Formula: 4 feet before a closed gate and after an opened gate.
Manual: Installation InstructionsQB ID: SC24-50